PHEROH MAKE PASS BOX

Features
Best to avoid cross contamination of product
UV tube
Wall grouted modules
Electromagnetic interlocking system with buzzer
SS.304/MS Powder coated
Stiffner for rigidity of base
Magnehelic gauge 0 - 50 mm w.g.

Description
The PHEROH make pass boxes are one of the safest contains clean zone cross contamination of material in transit. Pass box one door will be open at a time with a electromagnetic interlocking to avoid the cross contamination UV tube light will be on when both the doors are closed. Dynamic pass box with standard Mini pleat (Eff.99.997% down to 0.3m)& PHEROH make pre filter (Assign 90% eff) and Motor Blower assembly in options of 500 and 1000cfm with UV resistant glass windows validate check inside the pass box.
   
   
AIR CURTAIN
 
Features
Convenient hanging type modules on the doors.
Noise free effective air
Domestic purpose air curtain with velocity of 12 m/s thru nozzle.
Industrial purpose air curtain with velocity of 15 m/s thru nozzle

Description

PHEROH make air curtains, a preliminary method to avoid ross contamination having FRP Blowers ensure low noise, long life operation with single phase motors for domestic & three phase motors for industrial applications. Available in MS Powder coated & SS 304 also Flame Proof Air Curtains.
   
   


BIO HAZARD HOOD
 
Features
Heavy duty gauge SS304 construction of Bio safety cabinet
SS316 Tray will be provided for resistance of corrosion [optional]
Counter balance with glass shutter is proveded for protection during Handling the hazardous samples & contents.
30% or 10 % exhaust of class 100 air protect environment
Class 100 air from supply HEPA protects the product
Bio safety cabinet with virus burner to eliminate the hazardous viruses during the work.
Velocity 90 ± 20 below working area.

Description
Protect of the product, room and person during the work. Counter balance shutter prevents the laminar air goes out side. Perforted sheets on the working table sucks the outside air from opening of counter balance shutter & working table. Air will be curculated 70% in modle class II type B& 100% air exhust through HEPA filter in modle class II type A. Vertical laminar air flow Shield the protection and emission area against each other like barriers. Particals from out side do not get in (protection of product ) Product emissions are captured safety & led after (protection of persons & room avoidance from cross contamination in the room) & exhust of air through duct with HEPA Filter (protection of environment)
Class II type A bio safety cabinet, designed for use with bio safety level 1, 2 & 3 for biological or cytotoxic agent. With 30% or 10% Air exhaust class II type B bio safety cabinet, designed for 100% exhaust of Air.
   
   
 
LAMINAR AIR FLOW UNIT
 
Features
Compact, mobile transportable design.
Quiet operation 60 db
Light with 1000 lux & UV tube
Class 100 work surface
Available vertical, horizontal & mobile unit with battery backup
Counter balance wet glass shutter
MOC SS304, MS Powder coated
Velocity 90 ± 20 below working area.

Description
The application of these PHEROH make laminar air flow module is varios and takes place in the industrial manufacturing for the protection of the product in the following areas.
• Pharmaceutical, food, electrical, cosmetic industry, hospitals & also at    R&D work.
• Filling sections, Assembling processes, Demanding clean room    conditions & in which the product is not emitting
  The unit is ideal to protect the product from particular contamination   with the help of class 100 air & UV tube.
   
   
 
AIR SHOWER
 
 
Features
HEPA filter eff. 99.97% down to 0.3 micron
Pre filter eff. 85-95%
Motor blower assly : High capacity, FRP blower with aluminum impeller dia 7" x 4½" to produce 6000 FPM high velocity
Electrical supply 3 phase, 440 volt, 50Hz
Total 16 nozzles provided for single person entry level.
Hinge type door with glass window.
Hydraulic door closer

Description
Heavy duty Rigid Construction of aluminum door full glazing, Hinges & electromagnetic interlocking with emergency release switch. HEPA filter with eff. 99.97% down to 0.3 micron eliminate the dust. Emergency release switch prevent accidental access to clean zone area with 10-180 seconds adjustment of door release adjustable timer. Blower generated nozzle velocity 6000 FPM with 30 mm dia. nozzle effective clean the surface of the object.
   
   
 
APPAREL STORAGE CABINETS
 
Features
Class 100 air for storage garment & UV tube is provided to avoid bacterial contamination on garments.
Separate storage of aprons, Shoe covers & caps
MOC SS304, MS Powder coated
Hinge type or sliding type glass doors
Available in static or dynamic models

Description
PHEROH make apparel storage cabinet is use for storage of garments in hygienic conditions & Bacteria free environment, with HEPA filter & UV tube ensures kipping the garments free from particle as well as bacterial contamination
Internal size available : 2'[W] x 2'[D] x 4'[H] / 4'[w]x2'[D]x4'[H] /
                                      6'[W] x 2'[D] x 4'[H]
   
   
 
DISPENSING BOOTH


 
Features
Class 100 air
Air curtain effect, Antistatic PVC curtains is provided
Internal coving is provided
DOP port up stream is provided.
PHEROH make HEPA filter eff. 99.997% down to 0.3 micron as a supply filter
Initial Filter 90% DN To 10 microns.
Intermediate filter efficiency 95% DN To 5 Microns.
Motor blower assly : High capacity, FRP blower with aluminum impeller dia 7" x 4½"
Electrical supply 3 phase, 440 volt, 50Hz
Velocity 90 +/- 20% below working area
Antistatic PVC curtains [optional ]

Description
Equipment is used for dispensing of powder & chemicals to minimize the risk of contaminating of the work area & ensures the health for working person under the laminar air flow. The equipment is based on 3 level of filtrations of air circulation. This ensures that the cloud or particles formed by the material dispensed is sucked form the pre filter, intermediate filter & supply with HEPA filter. magnehelic gauge will indicate the pressure difference between the filters. During the initial cycle we achieve class 100 air with velocity 90 +/- 20% below working area.
   
   
 
FAN FILTER UNIT
 
Features
FULL Aluminum Anodized body
Permanently lubricated direct drive radial blower, extremely low noise and vibration levels [ less than 60 db] due to proper construction, mounting technology & inbuilt cushion
Mini pleat hepa with eff. 99.997% down to 0.3 microns.
Pre filter with eff. 90% down to 10 micron
Ebm Nadi make radial blower motor
Velocity speed regulator is provided
Very light weight canopy [approx > 50 kg fo size 4' x 2']
Considerably reduce the height without affecting the performance.
Class 100 equipment
Tested as per US FED STD 209E
 
 
TECHNICAL SPECIFICATIONS
TYPE
UNITS
SPECS
CANOPY SIZE MM 1200 X 600 [ W X D ]
HEIGHT MM 350
WIDTH X DEPTH MM 1130 X 530
MOC   ALUMINUM/SS 304
ELECTRIC SUPPLY VOLTS 230V, SINGLE PHASE
FREQUENCY Hz 50
   
   
TESTING EQUIPMENTS
Following Test Equipment & Rig as required to fully meet above Test Standard are available with us :
   
1. Laser Based Automatic Reading Particle Counter.
make - Met One Model No. A2408 for the validation of Clean room & clean room equipment
2. Dop Generator make ATI
3. Photometer TDA - 2G make - Air Techniques Inc - USA for testing HEPA filter
4. Housing unit with Blower and Damper
5. Pre - filter as per BS 2831 standard & Velometer
6. Manometer (Pressure drop indicator)
7. Complete Test Rig Conforming to IS 7613 / BS 2831
8. Opacity Meter.
   
   
   
Designed by : MID  Hosted by : PBD  Promoted by : GID