PHEROH MAKE PASS BOX |
| Features |
 |
Best to avoid cross contamination of product |
 |
UV tube |
 |
Wall grouted modules |
 |
Electromagnetic interlocking system with buzzer |
 |
SS.304/MS Powder coated |
 |
Stiffner for rigidity of base |
 |
Magnehelic gauge 0 - 50 mm w.g. |
Description
The PHEROH make pass boxes are one of the safest contains clean zone cross contamination of material in transit. Pass box one door will be open at a time with a electromagnetic interlocking to avoid the cross contamination UV tube light will be on when both the doors are closed. Dynamic pass box with standard Mini pleat (Eff.99.997% down to 0.3m)& PHEROH make pre filter (Assign 90% eff) and Motor Blower assembly in options of 500 and 1000cfm with UV resistant glass windows validate check inside the pass box.
|
| |
|
| |
|
 |
AIR CURTAIN |
| |
| Features |
 |
Convenient hanging type modules on the doors. |
 |
Noise free effective air |
 |
Domestic purpose air curtain with velocity of 12 m/s thru nozzle. |
 |
Industrial purpose air curtain with velocity of 15 m/s thru nozzle |
Description
PHEROH make air curtains, a preliminary method to avoid ross contamination having FRP Blowers ensure low noise, long life operation with single phase motors for domestic & three phase motors for industrial applications. Available in MS Powder coated & SS 304 also Flame Proof Air Curtains.
|
| |
|
| |
|
 |
BIO HAZARD HOOD |
| |
| Features |
 |
Heavy duty gauge SS304 construction of Bio safety cabinet |
 |
SS316 Tray will be provided for resistance of corrosion [optional] |
 |
Counter balance with glass shutter is proveded for protection during Handling the hazardous samples & contents. |
 |
30% or 10 % exhaust of class 100 air protect environment |
 |
Class 100 air from supply HEPA protects the product |
 |
Bio safety cabinet with virus burner to eliminate the hazardous viruses during the work. |
 |
Velocity 90 ± 20 below working area. |
Description
Protect of the product, room and person during the work. Counter balance shutter prevents the laminar air goes out side. Perforted sheets on the working table sucks the outside air from opening of counter balance shutter & working table. Air will be curculated 70% in modle class II type B& 100% air exhust through HEPA filter in modle class II type A. Vertical laminar air flow Shield the protection and emission area against each other like barriers. Particals from out side do not get in (protection of product ) Product emissions are captured safety & led after (protection of persons & room avoidance from cross contamination in the room) & exhust of air through duct with HEPA Filter (protection of environment)
Class II type A bio safety cabinet, designed for use with bio safety level 1, 2 & 3 for biological or cytotoxic agent. With 30% or 10% Air exhaust class II type B bio safety cabinet, designed for 100% exhaust of Air.
|
| |
|
| |
|
|
| |
|
| |
|
| |
AIR SHOWER |
 |
| |
| Features |
 |
HEPA filter eff. 99.97% down to 0.3 micron |
 |
Pre filter eff. 85-95% |
 |
Motor blower assly : High capacity, FRP blower with aluminum impeller dia 7" x 4½" to produce 6000 FPM high velocity |
 |
Electrical supply 3 phase, 440 volt, 50Hz |
 |
Total 16 nozzles provided for single person entry level. |
 |
Hinge type door with glass window. |
 |
Hydraulic door closer |
Description
Heavy duty Rigid Construction of aluminum door full glazing, Hinges & electromagnetic interlocking with emergency release switch. HEPA filter with eff. 99.97% down to 0.3 micron eliminate the dust. Emergency release switch prevent accidental access to clean zone area with 10-180 seconds adjustment of door release adjustable timer. Blower generated nozzle velocity 6000 FPM with 30 mm dia. nozzle effective clean the surface of the object.
|
| |
|
| |
|
| |
APPAREL STORAGE CABINETS |
 |
| |
| Features |
 |
Class 100 air for storage garment & UV tube is provided to avoid bacterial contamination on garments. |
 |
Separate storage of aprons, Shoe covers & caps |
 |
MOC SS304, MS Powder coated |
 |
Hinge type or sliding type glass doors |
 |
Available in static or dynamic models |
Description
PHEROH make apparel storage cabinet is use for storage of garments in hygienic conditions & Bacteria free environment, with HEPA filter & UV tube ensures kipping the garments free from particle as well as bacterial contamination
Internal size available : 2'[W] x 2'[D] x 4'[H] / 4'[w]x2'[D]x4'[H] /
6'[W] x 2'[D] x 4'[H]
|
| |
|
| |
|
| |
DISPENSING BOOTH |
 |
| |
| Features |
 |
Class 100 air |
 |
Air curtain effect, Antistatic PVC curtains is provided |
 |
Internal coving is provided |
 |
DOP port up stream is provided. |
 |
PHEROH make HEPA filter eff. 99.997% down to 0.3 micron as a supply filter |
 |
Initial Filter 90% DN To 10 microns. |
 |
Intermediate filter efficiency 95% DN To 5 Microns. |
 |
Motor blower assly : High capacity, FRP blower with aluminum impeller dia 7" x 4½" |
 |
Electrical supply 3 phase, 440 volt, 50Hz |
 |
Velocity 90 +/- 20% below working area |
 |
Antistatic PVC curtains [optional ] |
Description
Equipment is used for dispensing of powder & chemicals to minimize the risk of contaminating of the work area & ensures the health for working person under the laminar air flow. The equipment is based on 3 level of filtrations of air circulation. This ensures that the cloud or particles formed by the material dispensed is sucked form the pre filter, intermediate filter & supply with HEPA filter. magnehelic gauge will indicate the pressure difference between the filters. During the initial cycle we achieve class 100 air with velocity 90 +/- 20% below working area.
|
| |
|
| |
|
| |
FAN FILTER UNIT |
 |
| |
| Features |
 |
FULL Aluminum Anodized body |
 |
Permanently lubricated direct drive radial blower, extremely low noise and vibration levels [ less than 60 db] due to proper construction, mounting technology & inbuilt cushion |
 |
Mini pleat hepa with eff. 99.997% down to 0.3 microns. |
 |
Pre filter with eff. 90% down to 10 micron |
 |
Ebm Nadi make radial blower motor |
 |
Velocity speed regulator is provided |
 |
Very light weight canopy [approx > 50 kg fo size 4' x 2'] |
 |
Considerably reduce the height without affecting the performance. |
 |
Class 100 equipment |
 |
Tested as per US FED STD 209E |
 |
|
|
| |
TECHNICAL SPECIFICATIONS
TYPE |
UNITS |
SPECS |
| CANOPY SIZE |
MM |
1200 X 600 [ W X D ] |
| HEIGHT |
MM |
350 |
| WIDTH X DEPTH |
MM |
1130 X 530 |
| MOC |
|
ALUMINUM/SS 304 |
| ELECTRIC SUPPLY |
VOLTS |
230V, SINGLE PHASE |
| FREQUENCY |
Hz |
50 |
|
| |
|
| |
|
TESTING EQUIPMENTS |
| Following Test Equipment & Rig as required to fully meet above Test Standard are available with us : |
| |
|
| 1. |
Laser Based Automatic Reading Particle Counter. |
|
make - Met One Model No. A2408 for the validation of Clean room & clean room equipment |
| 2. |
Dop Generator make ATI |
| 3. |
Photometer TDA - 2G make - Air Techniques Inc - USA for testing HEPA filter |
| 4. |
Housing unit with Blower and Damper |
| 5. |
Pre - filter as per BS 2831 standard & Velometer |
| 6. |
Manometer (Pressure drop indicator) |
| 7. |
Complete Test Rig Conforming to IS 7613 / BS 2831 |
| 8. |
Opacity Meter. |
|
| |
|
| |
|
| |
|